D C+ 68/68 AAA/AAA M70x2
- Fire Rating
- EI 90
- Sound Class R'w
- 65
- Sound Class R'w+C
- 61
- Rule Type
- C+
- Clothing
- Standard plaster (A)
- Maximum height: 450 s
- 3.6
- Maximum height: 600 s
- 3
- Record Type
- at least 225
- Wall Construction
- D
- Apparent dimension
- 303
- Rule Dimension
- 68
- * = At least 10 mm between the frames
Model Details D CF 303 MFull
- Sound Class R'w
- 65 dB
- Frame
- CF
- Disc cladding
- 3+3
Corners, exterior/interior
D 202:1- a. Corner guards
- b. Corner rule with dry joint sealing
- c. Distance ≤ 300 mm
Corners, exterior/interior
D 202:2- a. Corner guards
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
- d. Distance ≤ 300 mm
Toward the floor
D 202:3- a. Gap ≥ 10 mm depending on wall type
- b. Joint ≥ 20 mm, with mineral wool Not required for concrete ≥ 250 mm
- c. Mounting spacing: 400 mm
- d. Sound insulation, Rail with dry joint sealing
- e. Concrete ≥ 150 mm
For lightweight ceilings and suspended ceilings
D 202:4- a. Concrete ≥ 150 mm
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Mineral wool ≥ 45 mm.
- e. Min. 2 x 12.5 mm gypsum board
For heavy-duty ceilings
D 202:5- a. Concrete ≥ 250 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
Against an interior wall with a lightweight structure
D 202:6- a. Adjacent wall with at least the same sound rating
- b. Mineral wool ≥ 2 x 70 mm
- c. Corner rule with dry joint sealing
Against a lightweight interior wall
D 202:7- a. Adjacent wall with at least the same sound rating
- b. Mineral wool ≥ 2 x 70 mm
- c. Mounting spacing: 400 mm
- d. Sound insulation, Rail with dry joint sealing
Against a heavy-duty wall
D 202:8- a. Partition wall, concrete ≥ 150 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
- d. Joint ≥ 20 mm, with mineral wool. Not required for concrete ≥ 250 mm
Against an interior wall/exterior wall with a shear wall
D 202:9- a. Min. 2 x 12.5 mm gypsum board
- b. Vapor barrier in exterior wall construction
- c. Corner rule with dry joint sealing
- d. Clearance ≥ 10 mm, taking thermal insulation into account
- e. Thermal Insulation
Against an exterior wall with a lightweight construction
D 202:10- a. Min. 2 x 12.5 mm gypsum board
- b. Vapor barrier
- c. Corner rule with dry joint sealing
- d. Windbreak, exterior panel
- e. Thermal Insulation
Against an exterior wall with a utility layer
D 202:11- a. Min. 2 x 12.5 mm gypsum board
- b. Vapor barrier
- c. Thermal Insulation
- d. Windbreak, exterior panel
Toward/past a pillar/beam
D 202:12- a. Cavity ≥ 40 mm, filled with mineral wool
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing