E C+ 160/160 AA/AA M95
- Fire Rating
- EI 60
- Sound Class R'w
- 52
- Rule Type
- C+
- Clothing
- Standard plaster (A)
- Maximum height: 450 s
- 61
- Maximum height: 600 s
- 61
- Record Type
- 210
- Wall Construction
- E
- Apparent dimension
- 202
- Rule Dimension
- 160
- 1 = Contact Europrofil if you need a taller wall.
Model Specifications E C+ 202 M2-3 52 dB
- Sound Class R'w
- 52 dB
- Frame
- C+
- Disc cladding
- 2+2
Corners, exterior/interior
E 202:1- a. Corner guards
- b. Mineral wool by type designation
- c. Sound insulation, Rail with dry joint sealing
- d. Mounting distance: 400 mm
Corners, exterior/interior
E 202:2- a. Corner guards
- b. Corner rule with dry joint sealing
- c. Sound insulation, Rail with dry joint sealing
- d. Distance ≤ 600 mm
- e. Mineral wool by type designation
Toward the floor, 52 dB
E 202:3A- a. Mineral wool by type designation
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Concrete: ≥ 160 mm
Toward the floor, 52 dB
E 202:3B- a. Mineral wool by type designation
- b. Mounting spacing: 400 mm.
- c. Soundproofing, dry joint sealing
- d. Joint ≥ 20 mm, with mineral wool. Not required for concrete ≥ 160 mm.
- e. Concrete ≥ 90 mm.
For ceilings/suspended ceilings with a lightweight construction, 52 dB
E 202:4- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall
- c. Vapor barrier in exterior roof construction
- d. Soundproofing, dry joint sealing
- e. Mounting distance: 400 mm
- f. Mineral wool by type designation
For heavy-duty ceilings
E 202:5- a. Concrete: ≥ 160 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
- d. Mineral wool by type designation
Against a lightweight interior wall, 52 dB
E 202:6- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Mineral wool ≥ 95 mm
- c. Mineral wool by type designation
- d. Soundproofing, dry joint sealing
- e. Mounting spacing: 400 mm.
- f. Gap ≥ 10 mm; this also applies to tracks on ceilings and floors
- g. Gaps ≥ 25 mm filled with mineral wool
Against a heavy-duty wall, 52 dB
E 202:7A- a. Concrete: ≥ 160 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mineral wool by type designation
- d. Mounting distance: 400 mm
Against a heavy-duty wall, 52 dB
E 202:7B- a. Concrete ≥ 90 mm
- b. Joint ≥ 20 mm, with mineral wool Not required for concrete ≥ 160 mm
- c. Soundproofing, dry joint sealing
- d. Mounting distance: 400 mm
Against an interior wall/exterior wall with a shear wall, 52 dB
E 202:8- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Thermal insulation.
- c. Vapor barrier in exterior wall construction
- d. Mineral wool by type designation
- e. Soundproofing, dry joint sealing
- f. Mounting, 400 mm
- g. Gap ≥ 10 mm; this also applies to tracks on ceilings and floors
- h. Clearance of ≥ 10 mm to accommodate thermal insulation
Against a lightweight exterior wall, 52 dB
E 202:9- a. At least 1 x 12.5 mm gypsum board
- b. Vapor barrier
- c. Corner rule with dry joint sealing
- d. Mineral wool by type designation
- e. With 2 x 12.5 mm gypsum board (a), studs do not need to be placed in line with the wall
- f. Soundproofing, dry joint sealing
- g. Windbreak, exterior panel
- h. Thermal insulation
Against an exterior wall with an insulation layer, 52 dB
E 202:10- a. At least 2 x 12.5 mm gypsum board with a gap of ≥ 10 mm. This gap requirement also applies to tracks at the ceiling and floor.
- b. Vapor barrier
- c. Soundproofing, dry joint sealing
- d. Mineral wool by type designation
- e. Mounting distance: 400 mm
- f. Thermal insulation.
- g. Windbreak, exterior panel
Against a column/beam
E 202:11- a. Concrete: ≥ 160 mm / wall thickness
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Mineral wool by type designation
Toward/past a pillar/beam
E 202:12- a. Cavities ≥ 20 mm, filled with mineral wool where applicable
- b. Mounting spacing: 400 mm
- c. Mineral wool by type designation
- d. Soundproofing, dry joint sealing