E C+ 75/75 AA/AA M0
- Fire Rating
- EI 60
- Sound Class R'w
- 40
- Rule Type
- C+
- Clothing
- Standard plaster (A)
- Maximum height: 450 s
- 4.6
- Maximum height: 600 s
- 4
- Record Type
- 125
- Wall Construction
- E
- Apparent dimension
- 202
- Rule Dimension
- 75
Model Specifications E CF 202 M0 40 dB
- Sound Class R'w
- 40 dB
- Frame
- CF
- Disc cladding
- 2+2
Corners, exterior/interior
E 202:1- a. Corner guards
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
Corners, exterior/interior
E 202:2- a. Corner guards
- b. Corner rule with dry joint sealing
- c. Distance ≤ 600 mm
Toward the floor, 40 dB
E 202:3- a. Mounting distance: 400 mm
- b. Sound insulation, Track with dry joint sealing
- c. Concrete: ≥ 100 mm
For lightweight ceilings/suspended ceilings, 40 dB
E 202:4- a. At least 1 x 12.5 mm gypsum board
- b. Mineral wool ≥ 45 mm, 120 mm on either side of the wall
- c. Vapor barrier in exterior roof construction
- d. Mounting distance: 400 mm
- e. Sound insulation, Rail with dry joint sealing
For heavy-duty ceilings
E 202:5- a. Concrete: ≥ 100 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
Against a lightweight interior wall, 40 dB
E 202:6- a. At least 1 x 12.5 mm gypsum board
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm.
- d. Mineral wool ≥ 45 mm in two stud cavities
Against a heavy-duty wall, 40 dB
E 202:7- a. Concrete: ≥ 100 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
Against an interior wall/exterior wall with a shear wall, 40 dB
E 202:8- a. At least 1 x 12.5 mm gypsum board
- b. Vapor barrier in exterior wall construction
- c. Mounting spacing: 400 mm
- d. Sound insulation, Rail with dry joint sealing
- e. Clearance ≥ 10 mm, taking thermal insulation into account.
- f. Thermal Insulation
Against a lightweight exterior wall, 40 dB
E 202:9- a. At least 1 x 12.5 mm gypsum board
- b. Thermal insulation
- c. Vapor barrier
- d. Mounting distance: 400 mm
- e. Sound insulation, Rail with dry joint sealing
- f. Windbreak, exterior panel
Against an exterior wall with an insulation layer, 40 dB
E 202:10- a. At least 1 x 12.5 mm gypsum board
- b. Thermal insulation
- c. Vapor barrier
- d. Mounting distance: 400 mm
- e. Sound insulation, Rail with dry joint sealing
- f. Windbreak, exterior panel.
Against a column/beam
E 202:11- a. Concrete: ≥ 120 mm / wall thickness
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
Toward/past a pillar/beam
E 202:12- a. Cavities ≥ 20 mm, filled with mineral wool where applicable
- b. Mounting spacing: 400 mm
- c. Soundproofing, dry joint sealing