E C+ 75/75 AA/AA M70
- Fire Rating
- EI 60
- Sound Class R'w
- 44-483
- Rule Type
- C+
- Clothing
- Standard plaster (A)
- Maximum height: 450 s
- 4.6
- Maximum height: 600 s
- 4
- Record Type
- 125
- Wall Construction
- E
- Apparent dimension
- 202
- Rule Dimension
- 75
- 3 = The higher sound class can be achieved if great care is taken with the connection details. Adjacent building elements must have performance at least equivalent to that of the wall.
Model Specifications E C+ 202 Mfull 48 dB
- Sound Class R'w
- 48 dB
- Frame
- C+
- Disc cladding
- 2+2
Corners, exterior/interior
E 202:1- a. Corner guards
- b. Cavity fully insulated
- c. Sound insulation, Rail with dry joint sealing
- d. Mounting distance: 400 mm
Corners, exterior/interior
E 202:2- a. Corner guards
- b. Corner rule with dry joint sealing
- c. Sound insulation, Rail with dry joint sealing
- d. Distance ≤ 600 mm
- e. Cavity fully insulated
Toward the floor, 48 dB
E 202:3- a. Cavity fully insulated
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Concrete: ≥ 120 mm
For ceilings/suspended ceilings with a lightweight construction, 48 dB
E 202:4- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall
- c. Vapor barrier in exterior roof construction
- d. Soundproofing, dry joint sealing
- e. Mounting distance: 400 mm
- f. Cavity fully insulated
For heavy-duty ceilings
E 202:5- a. Concrete: ≥ 120 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
- d. Cavity fully insulated
Against a lightweight interior wall, 48 dB
E 202:6- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Mineral wool ≥ 45 mm in two stud spaces
- c. Fully insulated cavity
- d. Soundproofing, dry joint sealing
- e. Mounting distance: 400 mm
Against a heavy-duty wall, 48 dB
E 202:7- a. Concrete: ≥ 120 mm
- b. Sound insulation, Track with dry joint sealing
- c. Fully insulated cavity
- d. Mounting distance: 400 mm
Against an interior wall/exterior wall with a shear wall, 48–52 dB
E 202:8- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Thermal insulation.
- c. Vapor barrier in exterior wall construction
- d. Cavity fully insulated
- e. Soundproofing, dry joint sealing
- f. Mounting, 400 mm
- g. Gap ≥ 10 mm; this also applies to tracks on ceilings and floors
- h. Clearance of ≥ 10 mm to accommodate thermal insulation
Against a lightweight exterior wall, 48 dB
E 202:9- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Vapor barrier.
- c. Soundproof, dry joint sealing
- d. Cavity fully insulated
- e. Mounting distance: 400 mm
- f. Thermal Insulation
- g. Windbreak, exterior panel
Against an exterior wall with an insulation layer, 48 dB
E 202:10- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Vapor barrier
- c. Soundproof, dry joint sealing
- d. Cavity fully insulated
- e. Mounting
- f. Thermal Insulation
- g. Windbreak, exterior panel
Against a column/beam
E 202:11- a. Concrete: ≥ 140 mm / wall thickness
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Cavity fully insulated
Toward/past a pillar/beam
E 202:12- a. Cavities ≥ 20 mm, filled with mineral wool where applicable
- b. Mounting spacing: 400 mm
- c. Fully insulated cavity
- d. Soundproofing, dry joint sealing