E C+ 75/75 AA/AA MR
- Fire Rating
- EI 60
- Sound Class R'w
- 44
- Rule Type
- C+
- Clothing
- Standard plaster (A)
- Maximum height: 450 s
- 4.6
- Maximum height: 600 s
- 4
- Record Type
- 125
- Wall Construction
- E
- Apparent dimension
- 202
- Rule Dimension
- 75
Model Specifications E C+ 202 MR 44 dB
- Sound Class R'w
- 44 dB
- Frame
- C+
- Disc cladding
- 2+2
Corners, exterior/interior
E 202:1- a. Corner guards
- b. Mineral wool strip, MR
- c. Sound insulation, Rail with dry joint sealing
- d. Mounting distance: 400 mm
Corners, exterior/interior
E 202:2- a. Corner guards
- b. Mineral wool strip, MR
- c. Distance ≤ 600 mm
- d. Corner rule with dry joint sealing
Toward the floor, 44 dB
E 202:3- a. Mineral wool strip, MR
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Concrete: ≥ 120 mm
For lightweight ceilings/suspended ceilings, 44 dB
E 202:4- a. At least 1 x 12.5 mm gypsum board with a slot ≥ 10 mm, or 2 x 12.5 mm gypsum boards without a slot.
- b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall.
- c. Vapor barrier in exterior roof construction
- d. Soundproofing, dry joint sealing
- e. Mounting distance: 400 mm
- f. Mineral wool strip, MR
For heavy-duty ceilings
E 202:5- a. Concrete: ≥ 120 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
- d. Mineral wool strip, MR
Against a lightweight interior wall, 44 dB
E 202:6- a. At least 1 x 12.5 mm gypsum board with a slot ≥ 10 mm, or 2 x 12.5 mm gypsum boards without a slot
- b. Mineral wool ≥ 45 mm in two stud spaces
- c. Mineral wool strip, MR
- d. Soundproofing, dry joint sealing
- e. Mounting distance: 400 mm
Against a heavy-duty wall, 44 dB
E 202:7- a. Concrete: ≥ 120 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mineral wool strip, MR
- d. Mounting distance: 400 mm
Against an interior wall/exterior wall with a shear wall, 44 dB
E 202:8- a. At least 1 x 12.5 mm gypsum board with a slot ≥ 10 mm, or 2 x 12.5 mm gypsum boards without a slot
- b. Vapor barrier in exterior wall construction
- c. Soundproofing, dry joint sealing
- d. Mineral wool strip, MR
- e. Mounting spacing: 400 mm.
- f. Distance ≥ 10 mm to accommodate thermal insulation
- g. Thermal Insulation
Against a lightweight exterior wall, 44 dB
E 202:9- a. At least 1 x 12.5 mm gypsum board with a slot ≥ 10 mm, or 2 x 12.5 mm gypsum boards without a slot
- b. Vapor barrier
- c. Soundproofing, dry joint sealing
- d. Mineral wool strip, MR
- e. Mounting distance: 400 mm
- f. Thermal insulation.
- g. Windbreak, exterior panel
Against an exterior wall with an insulation layer, 44 dB
E 202:10- a. At least 1 x 12.5 mm gypsum board with a slot ≥ 10 mm, or 2 x 12.5 mm gypsum boards without a slot
- b. Vapor barrier
- c. Soundproofing, dry joint sealing
- d. Mineral wool strip, MR
- e. Mounting distance: 400 mm
- f. Thermal Insulation
- g. Windbreak, exterior panel
Against a column/beam
E 202:11- a. Concrete: ≥ XXX mm / wall thickness
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Mineral wool strip, MR
Toward/past a pillar/beam
E 202:12- a. Cavities ≥ 20 mm, filled with mineral wool where applicable
- b. Mounting spacing: 400 mm
- c. Mineral wool strip, MR
- d. Soundproofing, dry joint sealing