E C+ 95/95 AA/AA M70
- Fire Rating
- EI 60
- Sound Class R'w
- 48
- Rule Type
- C+
- Clothing
- Standard plaster (A)
- Maximum height: 450 s
- 61
- Maximum height: 600 s
- 61
- Record Type
- 145
- Wall Construction
- E
- Apparent dimension
- 202
- Rule Dimension
- 95
- 1 = Contact Europrofil if you need a taller wall.
Model Specifications E C+ 202 Mfull 48 dB
- Sound Class R'w
- 48 dB
- Frame
- C+
- Disc cladding
- 2+2
Corners, exterior/interior
E 202:1- a. Corner guards
- b. Cavity fully insulated
- c. Sound insulation, Rail with dry joint sealing
- d. Mounting distance: 400 mm
Corners, exterior/interior
E 202:2- a. Corner guards
- b. Corner rule with dry joint sealing
- c. Sound insulation, Rail with dry joint sealing
- d. Distance ≤ 600 mm
- e. Cavity fully insulated
Toward the floor, 48 dB
E 202:3- a. Cavity fully insulated
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Concrete: ≥ 120 mm
For ceilings/suspended ceilings with a lightweight construction, 48 dB
E 202:4- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall
- c. Vapor barrier in exterior roof construction
- d. Soundproofing, dry joint sealing
- e. Mounting distance: 400 mm
- f. Cavity fully insulated
For heavy-duty ceilings
E 202:5- a. Concrete: ≥ 120 mm
- b. Sound insulation, Track with dry joint sealing
- c. Mounting spacing: 400 mm
- d. Cavity fully insulated
Against a lightweight interior wall, 48 dB
E 202:6- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Mineral wool ≥ 45 mm in two stud spaces
- c. Fully insulated cavity
- d. Soundproofing, dry joint sealing
- e. Mounting distance: 400 mm
Against a heavy-duty wall, 48 dB
E 202:7- a. Concrete: ≥ 120 mm
- b. Sound insulation, Track with dry joint sealing
- c. Fully insulated cavity
- d. Mounting distance: 400 mm
Against an interior wall/exterior wall with a shear wall, 48–52 dB
E 202:8- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Thermal insulation.
- c. Vapor barrier in exterior wall construction
- d. Cavity fully insulated
- e. Soundproofing, dry joint sealing
- f. Mounting, 400 mm
- g. Gap ≥ 10 mm; this also applies to tracks on ceilings and floors
- h. Clearance of ≥ 10 mm to accommodate thermal insulation
Against a lightweight exterior wall, 48 dB
E 202:9- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Vapor barrier.
- c. Soundproof, dry joint sealing
- d. Cavity fully insulated
- e. Mounting distance: 400 mm
- f. Thermal Insulation
- g. Windbreak, exterior panel
Against an exterior wall with an insulation layer, 48 dB
E 202:10- a. At least 2 x 12.5 mm gypsum board with a crack ≥ 10 mm
- b. Vapor barrier
- c. Soundproof, dry joint sealing
- d. Cavity fully insulated
- e. Mounting
- f. Thermal Insulation
- g. Windbreak, exterior panel
Against a column/beam
E 202:11- a. Concrete: ≥ 140 mm / wall thickness
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Cavity fully insulated
Toward/past a pillar/beam
E 202:12- a. Cavities ≥ 20 mm, filled with mineral wool where applicable
- b. Mounting spacing: 400 mm
- c. Fully insulated cavity
- d. Soundproofing, dry joint sealing