Wall type

E CF-1.0 145/145 F/F M0

Fire Rating
EI 60
Sound Class R'w
30
Rule Type
CF-1.0
Clothing
Fire plaster (F)
Maximum height: 450 s
81
Maximum height: 600 s
81
Record Type
175
Wall Construction
E
Apparent dimension
101
Rule Dimension
145
  • 1 = Contact Europrofil if you need a taller wall.

Model Specifications E CF 101 M0

Sound Class R'w
30 dB
Frame
CF
Disc cladding
1+1

Corners, exterior/interior

E 101:1
  1. a. Corner guards
  2. b. Mounting spacing: 400 mm

Corners, exterior/interior

E 101:2
  1. a. Corner guards
  2. b. Corner Rule
  3. c. Distance ≤ 600 mm

Toward the floor

E 101:3
  1. a. Mounting distance: 400 mm
  2. b. Concrete: ≤35 dB - ≥ 60 mm

For lightweight ceilings and suspended ceilings

E 101:4
  1. a. 1 x 12.5 mm drywall panel
  2. b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall
  3. c. Vapor barrier in exterior roof construction
  4. d. Mounting distance: 400 mm

For heavy-duty ceilings

E 101:5
  1. a. Concrete: 35 dB - ≥ 60 mm
  2. b. Mounting spacing: 400 mm

Against a lightweight interior wall

E 101:6
  1. a. at least 1 x 12.5 mm gypsum board
  2. b. Mounting spacing: 400 mm

Against a heavy-duty wall

E 101:7
  1. a. Concrete: ≤35 dB - ≥ 60 mm
  2. b. Mounting spacing: 400 mm

Against an interior wall/exterior wall with a shear wall

E 101:8
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier in exterior wall construction
  3. c. Mounting spacing: 400 mm
  4. d. Leave a gap of ≥ 10 mm to allow for thermal insulation.
  5. e. Thermal Insulation

Against an exterior wall with a lightweight construction

E 101:9
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier.
  3. c. Mounting spacing: 400 mm
  4. d. Thermal insulation.
  5. e. Windbreak, exterior panel.

Against an exterior wall with a utility layer

E 101:10
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier
  3. c. Mounting spacing: 400 mm
  4. d. Thermal Insulation
  5. e. Wind barrier, exterior panel

Against a column/beam

E 101:11
  1. a. Concrete, width ≥ 120 mm / wall thickness
  2. b. Mounting spacing: 400 mm

Toward/past a pillar/beam

E 101:12
  1. a. Cavities, filled with mineral wool where applicable
  2. b. Mounting spacing: 400 mm.