Wall type

E CF-1.0 45/45 A/A M0

Fire Rating
EI 30
Sound Class R'w
25-303
Rule Type
CF-1.0
Clothing
Standard plaster (A)
Maximum height: 450 s
3.3
Maximum height: 600 s
2.8
Record Type
70
Wall Construction
E
Apparent dimension
101
Rule Dimension
45
  • 3 = The higher sound class can be achieved if great care is taken with the connection details. Adjacent building elements must have performance at least equivalent to that of the wall.

Model Specifications E CF 101 M0

Sound Class R'w
30 dB
Frame
CF
Disc cladding
1+1

Corners, exterior/interior

E 101:1
  1. a. Corner guards
  2. b. Mounting spacing: 400 mm

Corners, exterior/interior

E 101:2
  1. a. Corner guards
  2. b. Corner Rule
  3. c. Distance ≤ 600 mm

Toward the floor

E 101:3
  1. a. Mounting distance: 400 mm
  2. b. Concrete: ≤35 dB - ≥ 60 mm

For lightweight ceilings and suspended ceilings

E 101:4
  1. a. 1 x 12.5 mm drywall panel
  2. b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall
  3. c. Vapor barrier in exterior roof construction
  4. d. Mounting distance: 400 mm

For heavy-duty ceilings

E 101:5
  1. a. Concrete: 35 dB - ≥ 60 mm
  2. b. Mounting spacing: 400 mm

Against a lightweight interior wall

E 101:6
  1. a. at least 1 x 12.5 mm gypsum board
  2. b. Mounting spacing: 400 mm

Against a heavy-duty wall

E 101:7
  1. a. Concrete: ≤35 dB - ≥ 60 mm
  2. b. Mounting spacing: 400 mm

Against an interior wall/exterior wall with a shear wall

E 101:8
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier in exterior wall construction
  3. c. Mounting spacing: 400 mm
  4. d. Leave a gap of ≥ 10 mm to allow for thermal insulation.
  5. e. Thermal Insulation

Against an exterior wall with a lightweight construction

E 101:9
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier.
  3. c. Mounting spacing: 400 mm
  4. d. Thermal insulation.
  5. e. Windbreak, exterior panel.

Against an exterior wall with a utility layer

E 101:10
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier
  3. c. Mounting spacing: 400 mm
  4. d. Thermal Insulation
  5. e. Wind barrier, exterior panel

Against a column/beam

E 101:11
  1. a. Concrete, width ≥ 120 mm / wall thickness
  2. b. Mounting spacing: 400 mm

Toward/past a pillar/beam

E 101:12
  1. a. Cavities, filled with mineral wool where applicable
  2. b. Mounting spacing: 400 mm.