Wall type

E CSP+ 70/70 AA/AA M0

Fire Rating
EI 60
Sound Class R'w
40-443
Rule Type
CSP+0.46
Clothing
Standard plaster (A)
Maximum height: 450 s
4.5
Maximum height: 600 s
3.9
Record Type
120
Wall Construction
E
Apparent dimension
202
Rule Dimension
70
  • 3 = The higher sound class can be achieved if great care is taken with the connection details. Adjacent building elements must have performance at least equivalent to that of the wall.

Model Specifications E CSP+ 202 M0 40 dB

Sound Class R'w
40 dB
Frame
C+
Disc cladding
2+2

Corners, exterior/interior

E 202:1
  1. a. Corner guards
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Mounting spacing: 400 mm

Corners, exterior/interior

E 202:2
  1. a. Corner guards
  2. b. Corner rule with dry joint sealing
  3. c. Distance ≤ 600 mm

Toward the floor, 40 dB

E 202:3
  1. a. Mounting distance: 400 mm
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Concrete: ≥ 100 mm

For lightweight ceilings/suspended ceilings, 40 dB

E 202:4
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Mineral wool ≥ 45 mm, 120 mm on either side of the wall
  3. c. Vapor barrier in exterior roof construction
  4. d. Mounting distance: 400 mm
  5. e. Sound insulation, Rail with dry joint sealing

For heavy-duty ceilings

E 202:5
  1. a. Concrete: ≥ 100 mm
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Mounting spacing: 400 mm

Against a lightweight interior wall, 40 dB

E 202:6
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Mounting spacing: 400 mm.
  4. d. Mineral wool ≥ 45 mm in two stud cavities

Against a heavy-duty wall, 40 dB

E 202:7
  1. a. Concrete: ≥ 100 mm
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Mounting spacing: 400 mm

Against an interior wall/exterior wall with a shear wall, 40 dB

E 202:8
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier in exterior wall construction
  3. c. Mounting spacing: 400 mm
  4. d. Sound insulation, Rail with dry joint sealing
  5. e. Clearance ≥ 10 mm, taking thermal insulation into account.
  6. f. Thermal Insulation

Against a lightweight exterior wall, 40 dB

E 202:9
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Thermal insulation
  3. c. Vapor barrier
  4. d. Mounting distance: 400 mm
  5. e. Sound insulation, Rail with dry joint sealing
  6. f. Windbreak, exterior panel

Against an exterior wall with an insulation layer, 40 dB

E 202:10
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Thermal insulation
  3. c. Vapor barrier
  4. d. Mounting distance: 400 mm
  5. e. Sound insulation, Rail with dry joint sealing
  6. f. Windbreak, exterior panel.

Against a column/beam

E 202:11
  1. a. Concrete: ≥ 120 mm / wall thickness
  2. b. Mounting spacing: 400 mm
  3. c. Sound insulation, Rail with dry joint sealing

Toward/past a pillar/beam

E 202:12
  1. a. Cavities ≥ 20 mm, filled with mineral wool where applicable
  2. b. Mounting spacing: 400 mm
  3. c. Soundproofing, dry joint sealing