Wall type

Z CF-1.0 145/120 AA/AA M145

Fire Rating
EI 60
Sound Class R'w
53
Rule Type
CF-1.0
Clothing
Standard plaster (A)
Maximum height: 450 s
7.4
Maximum height: 600 s
6.5
Record Type
195
Wall Construction
Z
Apparent dimension
202
Rule Dimension
145

Model Specifications Z CF 202 MFull

Sound Class R'w
53 dB
Frame
CF
Disc cladding
2+2

Corners, exterior/interior

Z 202:1
  1. a. Corner guards
  2. b. Corner rule with dry joint sealing
  3. c. Distance ≤ 600 mm

Corners, exterior/interior

Z 202:2
  1. a. Corner guards
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Mounting, p. 300
  4. d. Distance ≤ 300 mm

Toward the floor

Z 202:3
  1. a. Mounting distance: 400 mm
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Minimum 20 mm joint with mineral wool for concrete ≤ 160 mm
  4. d. Concrete ≥ 90 mm

For lightweight ceilings and suspended ceilings

Z 202:4
  1. a. 2 x 12.5 mm gypsum board with a slit ≥ 10 mm. Any suspended ceiling profiles must be slotted
  2. b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall
  3. c. Vapor barrier in exterior roof construction
  4. d. Sound insulation, Rail with dry joint sealing
  5. e. Alternating mounting, 400 mm
  6. f. Cavity fully insulated

For heavy-duty ceilings

Z 202:5
  1. a. Roof, concrete ≥ 160 mm
  2. b. Sound insulation, Track with dry joint sealing
  3. c. Alternating mounting, 400 mm
  4. d. Cavity fully insulated

Against a lightweight interior wall

Z 202:6
  1. a. 2 x 12.5 mm gypsum board
  2. b. Mineral wool ≥ 45 mm in two compartments
  3. c. Sound insulation, Rail with dry joint sealing
  4. d. Alternating mounting, 400 mm
  5. e. A gap of ≥ 10 mm; this also applies to tracks on the ceiling and floor.
  6. f. Distance ≥ 25 mm, filled with mineral wool.

Against a wall with a heavy-duty structure

Z 202:7
  1. a. Concrete ≥ 90 mm
  2. b. Minimum 20 mm joint with mineral wool for concrete ≤ 160 mm
  3. c. Sound insulation, Rail with dry joint sealing
  4. d. Alternating mounting, 400 mm

Against an interior wall/exterior wall with a stud wall

Z 202:8
  1. a. 2 x 12.5 mm gypsum board
  2. b. Thermal insulation
  3. c. Vapor barrier in exterior wall construction
  4. d. Sound insulation, Rail with dry joint sealing
  5. e. Alternating mounting, 400 mm
  6. f. Crack ≥ 10 mm; this also applies to tracks on the ceiling and floor.
  7. g. Clearance ≥ 10 mm, taking into account thermal insulation on exterior walls

Against an exterior wall with a lightweight construction

Z 202:9
  1. a. At least 1 x 12.5 mm gypsum board
  2. b. Vapor barrier
  3. c. Corner rule with dry joint sealing
  4. d. With 2 x 12.5 mm drywall, studs do not need to be placed in line with the wall
  5. e. Corner rule with dry joint sealing
  6. f. Thermal Insulation
  7. g. Windbreak, exterior panel

Against an exterior wall with a utility layer

Z 202:10
  1. a. 1 x 12.5 mm or 2 x 12.5 mm gypsum board. When using 2 x 12.5 mm gypsum board, studs do not need to be placed along the wall’s axis
  2. b. Vapor barrier.
  3. c. Sound insulation, track with dry joint sealing.
  4. d. Alternating mounting, 400 mm
  5. e. Thermal insulation.
  6. f. Windbreak, exterior panel

Against a column/beam

Z 202:11
  1. a. Concrete ≥ 180 mm / wall thickness
  2. b. Alternating mounting, 400 mm
  3. c. Sound insulation, Rail with dry joint sealing

Toward/past a pillar/beam

Z 202:12
  1. a. Cavity ≥ 20 mm, filled with mineral wool
  2. b. Mounting spacing: 400 mm
  3. c. Sound insulation, Rail with dry joint sealing