Z CF-1.0 145/120 AA/AA M145
- Fire Rating
- EI 60
- Sound Class R'w
- 53
- Rule Type
- CF-1.0
- Clothing
- Standard plaster (A)
- Maximum height: 450 s
- 7.4
- Maximum height: 600 s
- 6.5
- Record Type
- 195
- Wall Construction
- Z
- Apparent dimension
- 202
- Rule Dimension
- 145
Model Specifications Z CF 202 MFull
- Sound Class R'w
- 53 dB
- Frame
- CF
- Disc cladding
- 2+2
Corners, exterior/interior
Z 202:1- a. Corner guards
- b. Corner rule with dry joint sealing
- c. Distance ≤ 600 mm
Corners, exterior/interior
Z 202:2- a. Corner guards
- b. Sound insulation, Track with dry joint sealing
- c. Mounting, p. 300
- d. Distance ≤ 300 mm
Toward the floor
Z 202:3- a. Mounting distance: 400 mm
- b. Sound insulation, Track with dry joint sealing
- c. Minimum 20 mm joint with mineral wool for concrete ≤ 160 mm
- d. Concrete ≥ 90 mm
For lightweight ceilings and suspended ceilings
Z 202:4- a. 2 x 12.5 mm gypsum board with a slit ≥ 10 mm. Any suspended ceiling profiles must be slotted
- b. Mineral wool ≥ 45 mm, 1,200 mm on either side of the wall
- c. Vapor barrier in exterior roof construction
- d. Sound insulation, Rail with dry joint sealing
- e. Alternating mounting, 400 mm
- f. Cavity fully insulated
For heavy-duty ceilings
Z 202:5- a. Roof, concrete ≥ 160 mm
- b. Sound insulation, Track with dry joint sealing
- c. Alternating mounting, 400 mm
- d. Cavity fully insulated
Against a lightweight interior wall
Z 202:6- a. 2 x 12.5 mm gypsum board
- b. Mineral wool ≥ 45 mm in two compartments
- c. Sound insulation, Rail with dry joint sealing
- d. Alternating mounting, 400 mm
- e. A gap of ≥ 10 mm; this also applies to tracks on the ceiling and floor.
- f. Distance ≥ 25 mm, filled with mineral wool.
Against a wall with a heavy-duty structure
Z 202:7- a. Concrete ≥ 90 mm
- b. Minimum 20 mm joint with mineral wool for concrete ≤ 160 mm
- c. Sound insulation, Rail with dry joint sealing
- d. Alternating mounting, 400 mm
Against an interior wall/exterior wall with a stud wall
Z 202:8- a. 2 x 12.5 mm gypsum board
- b. Thermal insulation
- c. Vapor barrier in exterior wall construction
- d. Sound insulation, Rail with dry joint sealing
- e. Alternating mounting, 400 mm
- f. Crack ≥ 10 mm; this also applies to tracks on the ceiling and floor.
- g. Clearance ≥ 10 mm, taking into account thermal insulation on exterior walls
Against an exterior wall with a lightweight construction
Z 202:9- a. At least 1 x 12.5 mm gypsum board
- b. Vapor barrier
- c. Corner rule with dry joint sealing
- d. With 2 x 12.5 mm drywall, studs do not need to be placed in line with the wall
- e. Corner rule with dry joint sealing
- f. Thermal Insulation
- g. Windbreak, exterior panel
Against an exterior wall with a utility layer
Z 202:10- a. 1 x 12.5 mm or 2 x 12.5 mm gypsum board. When using 2 x 12.5 mm gypsum board, studs do not need to be placed along the wall’s axis
- b. Vapor barrier.
- c. Sound insulation, track with dry joint sealing.
- d. Alternating mounting, 400 mm
- e. Thermal insulation.
- f. Windbreak, exterior panel
Against a column/beam
Z 202:11- a. Concrete ≥ 180 mm / wall thickness
- b. Alternating mounting, 400 mm
- c. Sound insulation, Rail with dry joint sealing
Toward/past a pillar/beam
Z 202:12- a. Cavity ≥ 20 mm, filled with mineral wool
- b. Mounting spacing: 400 mm
- c. Sound insulation, Rail with dry joint sealing